16 analogue integrated inputs (voltage or current). Optional extra relay cards or MOSFET, which means that maximum functionality of 12 analogue and 64 digital functions is possible. Ideal for a Supervisor Operator System. Cabling via 32, 40, 50 or 72-pin plugs.

Applications

Suction and and cleaning vehicles Truck mounted cranes Concrete pumps Concrete vibrators Drilling machines Forestry and Agriculture vehicles Forestry haulage systems Bush-cutters Truck-mountes loader cranes Crushers  / Screeners Excavators / Diggers Port cranes Elevated Work Platforms (EWP) Provision cranes Cutting and pressing machines Ladders Tunnelling machines Scissor lifts Mixers Mobile Boat haulers Mobile Boat trolleys Offshore cranes Pipeline machines Sewer / Cleaning vehicles Break rock booms Rock-Breaker booms Tracked vehicles Tow vehicles Grinders for agriculture Railway automation Conveyor belts Handlers Forklift

Power supply 8-30 VDC
Antenna External; optional 1 or 5 meter extension cord
Max number of outputs 12 analog (voltage)
24 analog PWM (12 bi-directional axes)
40 digital
also available via CANopen interface
Rated current of STOP / Safety outputs STP_1 = 7.5 A (30 VDC)
STP_2 = 7.5 A (30 VDC)
SAF_1 = 7.5 A (30 VDC)
SAF_2 = 3 A (30 VDC)
Rated current of analoge outputs 2 A (30 VDC) - PWM
10 mA (28 VDC) - voltage
Rated current of digital outputs 4 A (30 VDC)
Safety performance of the STOP function (EN ISO 13849-1 / EN IEC 62061) up to PL e, cat. 4 / SIL 3
Safety category for the protection against unintended movements from standstill UMFS (EN ISO 13849-1 / EN IEC 62061) up to PL d, cat. 3 / SIL 2
Protection degree IP 65 (NEMA 4)
Operating and storage temperature operating: (-25 °C) ÷ (+55 °C) / (-13 °F) ÷ (+158 °F)
storage: (-40 °C) ÷ (+85 °C) / (-40 °F) ÷ (+185 °F)
Cabling 32, 50 or 72–pin plug
Dimensions 250 x 290 x 110 mm
9.8 x 11.4 x 4.3 in
Weight 3.8 kg
8.4 lb