Optimised for integration in a CAN / CANopen network. Maximum number of functions: 12 analogue and 64 digital (available via CANopen interface). Cabling via a 30-pole plug.

Applications

Suction and and cleaning vehicles Truck mounted cranes Concrete pumps Concrete vibrators Drilling machines Forestry and Agriculture vehicles Forestry haulage systems Bush-cutters Truck-mountes loader cranes Crushers  / Screeners Excavators / Diggers Port cranes Elevated Work Platforms (EWP) Provision cranes Cutting and pressing machines Ladders Tunnelling machines Scissor lifts Mixers Mobile Boat haulers Mobile Boat trolleys Offshore cranes Pipeline machines Sewer / Cleaning vehicles Break rock booms Rock-Breaker booms Tracked vehicles Tow vehicles Grinders for agriculture Railway automation Conveyor belts Handlers Forklift

Power supply 8-30 VDC
Antenna Dedicated
Antenna extension 1 or 5 meter
Max number of outputs 12 analog
64 digital (via CANopen)
Rated current of STOP / Safety outputs STP_1 = 8 A (30 VDC)
STP_2 = 8 A (30 VDC)
SAF_1 = 8 A (30 VDC)
SAF_2 = 3 A (30 VDC)
Safety performance of the STOP function (EN ISO 13849-1 / EN IEC 62061) up to PL e, cat. 4 / SIL 3
Safety category for the protection against unintended movements from standstill UMFS (EN ISO 13849-1 / EN IEC 62061) up to PL d, cat. 3 / SIL 2
Protection degree IP 65 (NEMA 4)
Operating and storage temperature operating: (-25 °C) ÷ (+55 °C) / (-13 °F) ÷ (+158 °F)
storage: (-40 °C) ÷ (+85 °C) / (-40 °F) ÷ (+185 °F)
Cabling 30-pin connector
Dimensions 153x148x55 mm
6.1x5.9x2.2 in
Weight 0.5 kg
1.1 Lb