Optimised for integration in a CAN / CANopen network. Maximum number of functions: 12 analogue and 64 digital (available via CANopen interface) and 4 MOSFET digital outputs. Cabling via a multi-pole plug, M12 connectors of cable gland and optional external antenna.

Applications

Suction and and cleaning vehicles Truck mounted cranes Concrete pumps Concrete vibrators Drilling machines Forestry and Agriculture vehicles Forestry haulage systems Bush-cutters Truck-mountes loader cranes Crushers  / Screeners Excavators / Diggers Port cranes Elevated Work Platforms (EWP) Provision cranes Cutting and pressing machines Ladders Tunnelling machines Scissor lifts Mixers Mobile Boat haulers Mobile Boat trolleys Offshore cranes Pipeline machines Sewer / Cleaning vehicles Break rock booms Rock-Breaker booms Tracked vehicles Tow vehicles Grinders for agriculture Railway automation Conveyor belts Handlers Forklift

"
Power supply 8-30 VDC
Antenna Internal antenna
1 or 5 meter extension cord. Optional
Max number of outputs 12 analog
64 digital (via CANopen) + 4 mosfet digital outputs
Rated current of STOP / Safety outputs SO_1 = 2 A (30 VDC)
SO_2 = 2 A (30 VDC)
Rated current of digital outputs 2 A (30 VDC)
Safety performance of the STOP function (EN ISO 13849-1 / EN IEC 62061) up to PL e, cat. 4 / SIL 3
Safety category for the protection against unintended movements from standstill UMFS (EN ISO 13849-1 / EN IEC 62061) up to PL d, cat. 3 / SIL 2
Protection degree IP 65 (NEMA 4)
Operating and storage temperature operating: (-25 °C) ÷ (+55 °C) / (-13 °F) ÷ (+158 °F)
storage: (-40 °C) ÷ (+85 °C) / (-40 °F) ÷ (+185 °F)
Cabling Customizable - possible solutions include M12 circular connector, 10-pin reduced plug, M12 connector (8+5pin), cable gland
Dimensions 128 x 143 x 63 mm
5.04 x 5.63 x 2.48 in
Weight 0.65 kg
1.43 Lb
"